Ex marking checker

Paste the marking from an equipment label to see what it means, and check if it suits your hazardous area.

Try:

Guidance only. The equipment certificate (including any special conditions) and IEC 60079-14 decide suitability, and selection and installation must be done by a competent person.

Reading Ex markings

What does an Ex marking mean?

An Ex marking tells you how a piece of equipment is protected against igniting an explosive atmosphere: the type of protection (such as db flameproof or ia intrinsic safety), the gas or dust group it is safe in, its temperature class or maximum surface temperature, and its equipment protection level (EPL), which decides the zones it can go in.

Which zones can Gb equipment be used in?

Equipment protection level Gb is suitable for Zone 1 and Zone 2. Ga is needed for Zone 0, and Gc is for Zone 2 only. For dust, Da covers Zone 20, Db Zone 21 and Dc Zone 22.

Can IIC equipment be used in an IIB area?

Yes. Gas group IIC equipment is also suitable for IIB and IIA. IIB equipment covers IIB and IIA, and IIA equipment covers only IIA. Equipment marked just "II" is suitable for all three.

Which temperature class do I need?

The equipment's maximum surface temperature must be below the ignition temperature of the gas. T1 is 450°C and T6 is 85°C; a T4 (135°C) device is suitable wherever T1, T2, T3 or T4 is required.

What does an X after the certificate number mean?

X means there are special conditions for safe use, written on the certificate. They must be followed when the equipment is installed. A U means a component certificate: the part is not complete equipment and must be built into certified equipment.